This article describes the reading or switching of inputs and outputs or registers and other things

Digital inputs and outputs ​

Read an input ​

The function getInput(inputName)/getOutput(outputName) is required to read out the value of an input/output. The function requires 1 parameter as a string. The string must describe an input/output, e.g. "INPUT_1","OUTPUT_4".

The function then returns a 0 or 1, depending on the current value of the input.

getInput("INPUT_1");

or

getOutput("OUTPUT_4");

Read an output ​

Use getOutput(outputName) to read an output. As shown in the preceding example, the name is passed as a string, such as OUTPUT_4, and the return value is 0 or 1.

Set or switch output ​

To switch an output, the setOutput command must be entered in the CodeArea.

The first parameter specifies which output is to be switched. Possible correct values are "OUTPUT_1" to "OUTPUT_14", as well as "TOOL_OUTPUT_1" and "TOOL_OUTPUT_2" for the UserIO.

The second parameter specifies the value of the corresponding output. Permissible values are 1 or 0

setOutput("OUTPUT_1", 1);

Register ​

Various registers are available in horstFX:

  • 64 Int Register
  • 64 Float Register
  • 128 Bool Register

Set register ​

The function

CommandIndexExample value
setFloatRegister(index, value)0-635.0
setIntRegister(index, value)0-635
setBoolRegister(index, value)0-127true

is required to write a value to a position in the register.

Read register ​

The function

CommandIndex
getFloatRegister(index)0-63
getIntRegister(index)0-63
getBoolRegister(index)0-127

is required to read a value from the corresponding register.


horstCOSMOS ​

Process data can be saved using the recordData(key, value, category) method. The key is a character string with which the data can be identified again later. The value to be saved is specified under value. This can be a character string or a number. Optionally, a character string can be specified as the third parameter as a category.

Data saved via recordData() is automatically synchronised daily with horstCOSMOS, our IOT platform. If this synchronisation is to take place immediately, this can be achieved using the sendRecordedData() function.

Example ​

recordData("data 1", 2.34, "pressure");
sendRecordedData();

Modbus ​

Modbus can be started using the command modbusConnect(ip, port, tcp). The parameter ip specifies the IP address as a string. The parameter port specifies the port as a number. The last parameter tcp specifies as a boolean whether you want a TCP connection (true) or a UDP connection (false).

The UnitID can be specified using the setUnitID() method. There are also the methods closeConnection(), readInputsDiscrete(ref, count), readInputDiscrete(ref), readCoils(ref, count), readCoil(ref), writeCoil(ref, value), readInputRegisters(ref, count), readInputRegister(ref), readRegisters(ref, count), readRegister(ref), writeRegisters(ref, values) und writeRegister(ref, value).

Example:

var m = modbusConnect("127.0.0.1", 8502, true);

showInfo(modbusReadInputsDiscrete(m, 0, 10).toString(16));
showInfo(modbusReadCoils(m, 1000, 3).toString());
modbusWriteCoils(m, 1000, [true,false,true]);
showInfo(modbusReadCoils(m, 1000, 3).toString());
showInfo(modbusReadInputRegisters(m, 600, 1).toString());
modbusWriteRegisters(m, 1000, [2,3]);
showInfo(modbusReadRegisters(m, 1000, 2).toString());