Safety and commissioning ​

Safety across the installation ​

The safety concept covers arms, tools, held loads, additional axes and the mobile base through setup, automatic operation and restart.

Protective signal path
  1. 01
    Protective deviceScanner · guard · emergency stop
  2. 02
    Safety interfaceTwo channels · monitored signals
  3. 03
    Protective responseStop · reset · release

Standards by responsibility ​

ScopeEngineering reference
Risk assessmentISO 12100:2010: hazards and risk reduction
Industrial roboticsISO 10218-1:2025: robot; ISO 10218-2:2025: application and cell
Functional safetyISO 13849-1:2023 / IEC 62061: safety-related controls, design and validation
Mobile operationISO 3691-4:2023: driverless industrial trucks and their systems
Fleet communicationVDA 5050: vehicle/fleet interface; explicitly not a safety standard

Derive required PLr/SIL from the risk assessment. Record applicable standards and editions, EU harmonisation status and validation results for installation acceptance.

Protective devices ​

FunctionSignal path
Warning fieldApplication / general I/O → process response
Protective fieldTwo-channel OSSD → assigned safety input → protective response
Emergency stop / enablingDedicated safe interfaces and operating-mode behavior

Control Safety I/O supports function assignment and read-back configuration. Hardware guides: nanoScan3, microScan3, guarding and safety distance.

Protective field design

Size protective fields and safety distances for the complete installation's stopping behavior. A warning-field signal alone does not establish a safety function.

CE support from industrial building blocks

fruitcore supplies its Robotic Solutions CE-compliant. Their manuals and delivered declarations support the agreed integration scope. Keep a machinery declaration of conformity distinct from the declaration of incorporation and assembly instructions for partly completed machinery (Machinery Directive, Article 13 / Annex II). The complete HDK installation receives its own risk assessment and conformity assessment; changes are evaluated against that scope.

EU transition: Regulation (EU) 2023/1230 generally applies from 20 January 2027.

Commissioning and evidence ​

Local software → Isaac Sim → target hardware → installation acceptance. Record timing, calibration, protective responses and restart under representative loads; Foxglove supports inspection and replay.

Sensor evidence ​

Make sensor results traceable
  1. 01
    IdentifySensor · tool · revision
  2. 02
    AlignTime · frame · calibration
  3. 03
    RecordSignal · event · conditions
  4. 04
    EvaluatePlots · latency · outcome

Record camera identity, transforms and observation age; for force/torque, units, frame, zero offset and known-load response. Keep configuration, operating limits, test conditions and acceptance results together. Continue with deployment and operation.