Safety and commissioning
Safety across the installation
The safety concept covers arms, tools, held loads, additional axes and the mobile base through setup, automatic operation and restart.
- Protective deviceScanner · guard · emergency stop
- Safety interfaceTwo channels · monitored signals
- Protective responseStop · reset · release
Standards by responsibility
| Scope | Engineering reference |
|---|---|
| Risk assessment | ISO 12100:2010: hazards and risk reduction |
| Industrial robotics | ISO 10218-1:2025: robot; ISO 10218-2:2025: application and cell |
| Functional safety | ISO 13849-1:2023 / IEC 62061: safety-related controls, design and validation |
| Mobile operation | ISO 3691-4:2023: driverless industrial trucks and their systems |
| Fleet communication | VDA 5050: vehicle/fleet interface; explicitly not a safety standard |
Derive required PLr/SIL from the risk assessment. Record applicable standards and editions, EU harmonisation status and validation results for installation acceptance.
Protective devices
| Function | Signal path |
|---|---|
| Warning field | Application / general I/O → process response |
| Protective field | Two-channel OSSD → assigned safety input → protective response |
| Emergency stop / enabling | Dedicated safe interfaces and operating-mode behavior |
Control Safety I/O supports function assignment and read-back configuration. Hardware guides: nanoScan3, microScan3, guarding and safety distance.
Protective field design
Size protective fields and safety distances for the complete installation's stopping behavior. A warning-field signal alone does not establish a safety function.
CE support from industrial building blocks
fruitcore supplies its Robotic Solutions CE-compliant. Their manuals and delivered declarations support the agreed integration scope. Keep a machinery declaration of conformity distinct from the declaration of incorporation and assembly instructions for partly completed machinery (Machinery Directive, Article 13 / Annex II). The complete HDK installation receives its own risk assessment and conformity assessment; changes are evaluated against that scope.
EU transition: Regulation (EU) 2023/1230 generally applies from 20 January 2027.
Commissioning and evidence
Local software → Isaac Sim → target hardware → installation acceptance. Record timing, calibration, protective responses and restart under representative loads; Foxglove supports inspection and replay.
Sensor evidence
- IdentifySensor · tool · revision
- AlignTime · frame · calibration
- RecordSignal · event · conditions
- EvaluatePlots · latency · outcome
Record camera identity, transforms and observation age; for force/torque, units, frame, zero offset and known-load response. Keep configuration, operating limits, test conditions and acceptance results together. Continue with deployment and operation.