Force/torque sensing
A wrist sensor captures the six-axis load (Fx, Fy, Fz, Tx, Ty, Tz) in N and N·m. It supports contact detection, insertion and process monitoring; finger tactile sensing adds the local contact distribution.
Three measurement principles
| Principle · manufacturer example | Application | Measurement quality · manufacturer specification |
|---|---|---|
| Strain gauge · ATI Axia80-M20 | Assembly and force-controlled processing | SI-500-20: 500 N transverse / 900 N axial / 20 N·m. Typical effective resolution 0.1 N / 0.005 N·m; accuracy better than 2% full scale. |
| Optical · OnRobot HEX-E / HEX-H | Sensitive contact detection or higher moment capacity | HEX-E: 200 N per force axis; typical noise-free resolution 0.2 N transverse / 0.8 N axial. Full-scale nonlinearity < 2%. Datasheet. |
| Piezoelectric · Kistler 9306A | Stiff quartz measurement chain for dynamic/quasistatic processes | Force linearity including hysteresis ≤±0.5% FSO; moment linearity ≤±1% FSO. Six-channel charge amplifier. Datasheet. |
Resolution describes detectable change; accuracy/linearity describes deviation from a reference. Compare like definitions, ranges and test conditions. These examples illustrate sensor selection; mounting and driver belong to the selected tool profile.
Include the tool load
Perpendicular lever arm, g = 9.81 m/s². Process and acceleration loads are added to this static load.
Select ranges for combined tool, payload and process loads. Compensation uses mass, centre of gravity, pose and sensor/tool transforms. Changing the reference point adds r × F to the moment.
Six axes, one observation
| Data | Content |
|---|---|
| Measurement | Six components, units, frame/reference point, calibration and compensation revision |
| Timing | Source/receive timestamp, clock domain, measured age, rate and filter delay |
| Validity | Overload/saturation, loss, restart and calibration status; timeout response |
Process sensing and protection
Force-controlled motion uses the supported controller path and application validation. Protective functions follow the installation's safety concept.
Continue with software integration and sensor evidence.