Skip to content

Use with AI

Use with AI

Control and interfaces ​

PLEXA Control executes robot operations; your application owns perception and task logic. Industrial I/O connects the surrounding machine, tools and protective devices.

Architecture and electronics ​

The architecture builds on HORST Control with an IPC and embedded mainboard. An application PC or Jetson provides additional compute. The electrical configuration assigns power, communication and safety connections to each arm, axis and peripheral.

Control and connections
  1. 01
    Application hostPC / IPC / Jetson
  2. 02
    Robot controlRobot interface · Control
  3. 03
    Robot and toolsMotion · status · I/O

Control hardware reference ​

HORST Control reference values. Use the selected PLEXA configuration's wiring diagram and power budget.

HardwareHORST Control reference · manual V1-3, §§5.8 / 11.1
Enclosure / environment460 × 315 × 175 mm; 9 kg; IP20; 5–40 °C; 10–75% RH
Supply115/230 V AC, 50–60 Hz; maximum 6.0 A at 230 V; maximum 1000 W
General I/O20 digital inputs, 18 outputs; 24 V signals
SafetyDedicated emergency-stop, protective-stop and enabling interfaces; four configurable safe inputs, six safe outputs including two relays
Network / serviceRJ45 Ethernet / TCP/IP; two USB 3.1 ports
Tool / panel2 × 2 configurable HORST tool I/O; 13.3-inch panel V1: 1920 × 1080 / IP20, V2: 2560 × 1600 / IP54; two USB 2.0 ports

Control manual · Product specification · I/O configuration

Electrical integration ​

Allocate voltage, peak current, grounding, shielding and connector pinning per device. Hands, vision compute and an AMR use their specified supplies; a 48 V hand needs its own suitable power path. Reassigning configurable safety I/O to general I/O removes that channel's safety function.

Interfaces by responsibility ​

Application → robot

Robot access with defined command ownership, status and fault handling.

PLC → Control

Digital I/O and the documented Advanced Interfaces: PROFINET, Modbus and XML-RPC.

Peripheral → host / controller

Ethernet or device bus. EtherCAT devices use a compatible master and driver.

Protective device → safety input

Dedicated safe channels and the assigned protective response of the installation.

Continue with software integration and tools and hands.